JLC / NLC IP Parameters

 

The IP parameters are calculated using the program lcopt, written by K. Yokoya, and verified with GuineaPig and analytic expressions.  Parameters are listed for repetition rates of 120 Hz.  The luminosity values have roughly 5% dilution to account for beam jitter and IP tuning.

The present parameters were derived at the 11/2001 ISG meeting at KEK.  These parameters have been used for the TRC comparison and the USLCTOS study.   The parameters are also described in the NLC configurations documents.  The 2003 configuration is located at:  http://www-project.slac.stanford.edu/lc/local/documentation/2003_Doc.htm

 

High Energy IP Parameters
  Stage 1 Stage 2
CMS Energy (GeV) 500 1000
Site US Japan US Japan
Luminosity (1033) 20 25 30 25
Repetition Rate (Hz) 120 150 120 100
Bunch Charge (1010) 0.75 0.75
Bunches/RF Pulse 192 192
Bunch Separation (ns) 1.4 1.4
Loaded Gradient (MV/m) 50 50
Injected gex / gey (10-8) 300 / 2 300 / 2
gex at IP (10-8 m-rad) 360 360
gey at IP (10-8 m-rad) 4 4
bx / by at IP (mm) 8 / 0.11 13 / 0.11
sx / sy at IP (nm) 243 / 3.0 219 / 2.1
qx / qy at IP (nm) 32 / 28 17 / 20
sz at IP (um) 110 110
Uave 0.14 0.29
Pinch Enhancement 1.51 1.47
Beamstrahlung dB (%) 5.4 8.9
Photons per e+/e- 1.3 1.3
Two Linac Length (km) 14 28

 

Low energy IP parameters from 2003 configuration document.

 

Created: 07/03/98 by Tor Raubenheimer
Modified: 05/06/04 by Tor Raubenheimer